ACCESSORIES
Automatic Circuit Recloser PMSet U-Series Recloser
The switchgear is operated by a magnetic actuator, which produces an opening and closing action. Switching occurs when a controlled pulse is sent through the open/close actuator from storage capacitors in the PowerLogic ADVC. When closed, the switch is latched magnetically. Spring loaded pushrods provide contact loading on the interrupters.
A current transformer (CT) and a capacitive voltage transformer (CVT) are moulded into the CT-housing.
These are monitored by the PowerLogic ADVC for protection, remote monitoring, and display. An auxiliary voltage supply of 115/230 V AC is required to power the control unit. Where this is inconvenient, an additional voltage transformer can be provided.
The recloser is supplied with copper stems or optional cable clamp connectors.
Mounting brackets for lightning arresters are optionally available.
The switchgear contact position is shown by a large, clearly visible external pointer. The main tank is equipped with a manual trip lever that can be operated from ground level by a hook stick which performs open and lockout simultaneously. The mechanical lever electronically inhibits both local and remote closing. The position of the lever is indicated to the PowerLogic ADVC by an associated micro-switch. The manual trip ring remains in the down position until it is physically returned to the normal position by the operator. The PowerLogic ADVC interfaces to the switchgear via the control cable and connects to the Switch Cable Entry Module (SCEM) in the base of the tank via a covered plug/socket sealing arrangement on both the PowerLogic ADVC and the switchgear.
The SCEM uses non-volatile memory to store the relevant calibration data, ratings, and number of operations. The SCEM also provides the first stage of electrical isolation and shorting electronics too short the CTs and CVTs in the event the control cable is disconnected while current is flowing through the switchgear.
PowerLogic ADVC Features
Two different Operator Interfaces are available, these are:
1) setVUE Operator Interface and
– Based on the field-proven operator panels in the previous controllers, this menu-driven interface with large LCD display offers a familiar look and feel.
2) flexVUE Operator Interface
– 20 Status Lamps provide a quick snapshot of the protection and controller status.
– 12 Quick Action Keys are available to execute frequently used actions such as “Remote control” On/Off, “RECLOSE” On/Off, and so on. Each key has its own status lamp to indicate the On/Off state.
– The Status Lamps and Quick Action Keys are customizable.
– It is possible to access Event and Measurement data and modify settings.
Auto Recloser Pole Mounting Details: U-Series
Configuring Delayed Operation for ADVC Controller with FlexVue Panel | Schneider Electric Support
Load Break Switch (LBS) S&S 11-38kV SF6 Gas Insulated
Manual Type
LBS 25.8kV 630A 16kA/s Load Break Switch, Sealed Type, Porcelain Type, Manual Control.
Included Accessories: LBS Mounting Bracket, 06 Terminals (be integrated available on 6 Bushings).
Auto Type
LBS 25.8kV 630A 16kA/s Load Break Switch, Sealed Type, Polymer Type, included control cabinet with SCADA connection function, following IEC 60870-5-101 & 104 protocol
Included accessories: LBS mounting bracket, 06 terminals (2-hole terminal type, designed to connect by compression terminal), control cabinet mounting bracket, power supply cable, and control cable.
Lightning Arrester (LA) - Fuse Cutout (FCO) - Fuse Cutout With Arc Chute (LBFCO) - DISCONNECT SWITCH (DS)
Related Products
Auto Recloser NOVA 27i, Cooper
Auto Recloser ABB
LBS SF6 gas-insulated insulated-Korea
LBS with ADVC Controller, Schneider